Technical parameters
Signal mode: Four-wire system (24VDC+4~20mA);
Output signal: 4-20mA (active output) / 485 modbus RTU communication;
Power supply: 24VDC (External resistance components cannot be loaded or PLC cannot be connected in series);
Concentration range: 0-100%(at 20℃). According to the usage conditions, it can be calibrated to a certain range segment.
Density range: 0-2g/ml. According to the usage conditions, it can be calibrated to a certain range segment.
Concentration accuracy: 0.5%, resolution: 0.1%, repeatability: 0.2%;
Density accuracy: 0.003g /ml, resolution: 0.0001, repeatability: 0.0005;
Explosion-proof grade: Flameproof ExdII BT6
Applicable pressure: <1Mpa;
Applicable temperature: 0 to 60℃ (liquid state) Ambient temperature: -40 to 85℃
Medium viscosity: <5000mpa·s;
Technical parameters
Signal mode: Four-wire system (24VDC+4~20mA);
Output signal: 4-20mA (active output) / 485 modbus RTU communication;
Power supply: 24VDC (External resistance components cannot be loaded or PLC cannot be connected in series);
Concentration range: 0-100%(at 20℃). According to the usage conditions, it can be calibrated to a certain range segment.
Density range: 0-2g/ml. According to the usage conditions, it can be calibrated to a certain range segment.
Concentration accuracy: 0.5%, resolution: 0.1%, repeatability: 0.2%;
Density accuracy: 0.003g /ml, resolution: 0.0001, repeatability: 0.0005;
Explosion-proof grade: Flameproof ExdII BT6
Applicable pressure: <1Mpa;
Applicable temperature: 0 to 60℃ (liquid state) Ambient temperature: -40 to 85℃
Medium viscosity: <5000mpa·s;

Product Features
It adopts a 4-wire system mode, with 4-20mA output transmission and RS485-Modbus RTU communication
Concentration value: 0-100.0% (20℃) display (1 decimal place); Real-time display of five-digit density values (four decimal places); Baume degree, current value and temperature
Real-time indication enables direct access to the instrument menu on-site for parameter setting and debugging. It is easy to operate and features pure water calibration, fine-tuning of measurement values, and temperature compensation functions
Online real-time measurement can be directly applied to production process control
The titanium alloy material of the parts in contact with liquids can be customized according to requirements

Copy product links