Technical parameters
Measurement range 0.01-20μS/cm (with 0.01 electrode) 20-200μS/cm (with 0.1 electrode) Conductivity meter 200-2000μS/cm (with 1.0 electrode) 2000-20000μS/cm (with 10.0 electrode) 6000-60,000 μS/cm (with '30.0 electrode;'
Resolution: 0.01μS/cm;
Basic instrument errors: Conductivity: ±3.0%FS, temperature: ±0.5℃;
Basic errors of electronic units: Conductivity: ±0.5%FS, temperature: ±0.3℃;
Automatic temperature compensation range: 0 to 99.9℃ (other temperatures can be customized), with 25℃ as the reference temperature.
Stability: ±1%FS/24H;
Signal output: 2 4-20mA channels, 1 RS485 channel, 1 RS232 channel (supporting Modbus protocol), printer (optional);
Power source: 220VAC±10%,50±1Hz, power ≤3W; 24VDC, power ≤1W (to be reserved); 12VDC, power ≤1W (to be reserved);
Instrument material: Main unit material: ABS;
Sensor cable: 10m shielded cable (optional, customizable to any length);
Working environment: Normal temperature and normal pressure;
Protection grade: Host protection IP65; Sensor protection: IP68;
Data browsing: Quickly view log, hourly, daily, monthly and annual traffic records;
Functions: Supports data export, supports operation record query, supports data collection, supports wireless transmission, supports micro printers;
Display meter working environment: Ambient temperature: -10 to 60℃; Relative humidity: Not more than 90%;
Technical parameters
Measurement range 0.01-20μS/cm (with 0.01 electrode) 20-200μS/cm (with 0.1 electrode) Conductivity meter 200-2000μS/cm (with 1.0 electrode) 2000-20000μS/cm (with 10.0 electrode) 6000-60,000 μS/cm (with '30.0 electrode;'
Resolution: 0.01μS/cm;
Basic instrument errors: Conductivity: ±3.0%FS, temperature: ±0.5℃;
Basic errors of electronic units: Conductivity: ±0.5%FS, temperature: ±0.3℃;
Automatic temperature compensation range: 0 to 99.9℃ (other temperatures can be customized), with 25℃ as the reference temperature.
Stability: ±1%FS/24H;
Signal output: 2 4-20mA channels, 1 RS485 channel, 1 RS232 channel (supporting Modbus protocol), printer (optional);
Power source: 220VAC±10%,50±1Hz, power ≤3W; 24VDC, power ≤1W (to be reserved); 12VDC, power ≤1W (to be reserved);
Instrument material: Main unit material: ABS;
Sensor cable: 10m shielded cable (optional, customizable to any length);
Working environment: Normal temperature and normal pressure;
Protection grade: Host protection IP65; Sensor protection: IP68;
Data browsing: Quickly view log, hourly, daily, monthly and annual traffic records;
Functions: Supports data export, supports operation record query, supports data collection, supports wireless transmission, supports micro printers;
Display meter working environment: Ambient temperature: -10 to 60℃; Relative humidity: Not more than 90%;
Product Features
Intelligence: A single-chip microprocessor is adopted to complete the measurement of conductivity values, temperature measurement and compensation
Dual high-impedance preamplifier: High input impedance, noise reduction, and strong anti-interference ability
Multiple calibration methods
Human-computer dialogue: The menu operation is simple. Users can operate it by following the prompts on the screen
Multi-parameter display on the same screen: Simultaneously display the conductivity value, temperature value and working status
The measurement range and the upper and lower limits of the alarm can be freely set. Upper and lower limit over-limit alarm prompts
Three sets of relay control switches, and the hysteresis control range is adjustable
Self-cleaning switch quantity setting, setting cleaning time and interval
Data storage, operation log, printing function
Multiple calibration methods are adopted to ensure measurement accuracy
Both Chinese and English menus are available