Technical parameters
Measurement accuracy: ±1.0%
Repeatability accuracy: ±0.1%
Applicable pressure: 0 to 20MPa, up to 40MPa for special applications.
Applicable temperature: -20 to 1200℃
Range ratio: 10:1, up to 20:1 in special circumstances;
Applicable pipe diameters: round and square pipes ranging from 12 to 15,000 mm;
Applicable medium: It can measure full tubes and bidirectional flow of liquids, gases and steam.
Probe material: 316L/TP317LN/ Hastelloy/chromium-nickel-iron/Titanium/manganese-El alloy/duplex stainless steel /314/PVDF
Technical parameters
Measurement accuracy: ±1.0%
Repeatability accuracy: ±0.1%
Applicable pressure: 0 to 20MPa, up to 40MPa for special applications.
Applicable temperature: -20 to 1200℃
Range ratio: 10:1, up to 20:1 in special circumstances;
Applicable pipe diameters: round and square pipes ranging from 12 to 15,000 mm;
Applicable medium: It can measure full tubes and bidirectional flow of liquids, gases and steam.
Probe material: 316L/TP317LN/ Hastelloy/chromium-nickel-iron/Titanium/manganese-El alloy/duplex stainless steel /314/PVDF

Product Features
The integrated flow sensor can be directly connected to the transmitter without the need for installation accessories such as pressure lead pipes
Bidirectional measurement can be carried out
The unique probe cross-section design can generate a larger differential pressure value under the same conditions, ensuring a stable differential pressure signal
The integrated dual-chamber probe ensures no leakage at high/low pressure
High-stability sensors, with a maximum material thickness of 5.7mm
The sensor materials are diverse to ensure the long-term stability of accuracy when measuring corrosive media and high-temperature and high-pressure media
It features low pressure loss, energy conservation and consumption reduction, as well as low operating costs
Easy to install, low cost, and basically maintenance-free in later operation
It can be installed and removed under pressure
It can measure both the condensation of water and dirty media
The large-diameter sensing pressure tapping hole (up to 8.5mm) ensures that the measured dirty medium is not easily clogged and has a self-cleaning function